Air & Solid-Insulated RMU

XGN□-12/24 Indoor Air-Insulated Ring Main Unit

Box-type fixed metal-enclosed RMU for 12/24 kV ring networks and terminal distribution — GB 3906 / IEC 298 compliant with full five-prevention interlocking; SF6 maintenance-free load switch inside.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Compact good-looking cabinets; assembled-row enclosure protection above IP3X
  • Modular upper/lower units for easy installation and maintenance; riveted frame guarantees rigidity
  • Integrated LV compartment for secondary elements, with extensible instrument room for more protection units
  • Pressure-relief duct available; SF6 maintenance-free load switch — economical and reliable
  • Simple operation with complete five-prevention interlocking
At a glance

Built to perform, year after year

12 / 24kV
Rated voltage
50Hz
Frequency
> IP3X
Assembled-row protection
SF6 免维护
Load switch
A closer look

Engineered around safety, efficiency and uptime

Overview

The XGN□-12/24 is a box-type fixed AC metal-enclosed ring-main switchgear (12 kV, 50 Hz) for three-phase ring networks, terminal distribution grids and industrial loads — receiving, distributing and protecting power, and equally suited for installation inside box substations. It complies with GB 3906 and IEC 298 and provides the full five-prevention interlock.

Executive standards

GB 3906-2006 — 3.6–40.5 kV AC metal-enclosed switchgear and controlgear
IEC 60298-1990 — AC metal-enclosed switchgear and controlgear, 1–52 kV
GB/T 11022-2011 — Common technical requirements for HV switchgear and controlgear

Product features

Compact good-looking cabinets; assembled-row enclosure protection above IP3X
Modular upper/lower units for easy installation and maintenance; riveted frame guarantees rigidity
Integrated LV compartment for secondary elements, with extensible instrument room for more protection units
Pressure-relief duct available; SF6 maintenance-free load switch — economical and reliable
Simple operation with complete five-prevention interlocking

Structure

Compartments — busbar, load-switch / breaker, cable, operating & interlock mechanisms and LV control — are steel-plate segregated so faults cannot spread. Busbars run horizontally on top for easy extension. The epoxy-cast SF6 load switch shows contact status through transparent end covers; gas-density gauges with alarm contacts are optional. The mid-mounted breaker compartment accepts vacuum or SF6 breakers with spring mechanisms and reclosing. The roomy cable compartment takes simple unshielded terminations plus arresters, CTs and earthing switches, with viewing window and safety interlocks on the door.

Service conditions

Altitude ≤ 1000 m (state special needs at ordering)
Ambient −35 °C … +45 °C, max daily mean ΔT ≤ 25 K
Daily RH ≤ 95 %, monthly ≤ 90 %; seismic intensity 8
No severe vibration/impact, fire, chemical corrosion or explosion hazard

Ready to power your next project?